Clarity Software

Clarity software for system control and data acquisition

  • Fully featured data acquisition software
  • Up to 4 independent timebases
  • Multiple instrument control
  • GLP, 21 CFR part 11 compliance

Clarity Software

Details

Clarity from DataApex is an advanced modular software package for data acquisition, data processing and instrument control. Up to four independent LC systems each with up to 12 detectors can be simultaneously connected. Optional ‘Control modules’ provide integrated control of selected instruments, ‘Extensions’ provide specialized functionality for PDA or GPC analysis. Its wide range of data acquisition interfaces (A/D converters, LAN, USB, and RS232) allows connection to virtually any chromatograph.

To familiarise with Clarity a few hands-on sessions are available. Details are in document 195_7010 'Clarity hands-on training'. A number of screen recordings in the tutorial section show how specific tasks are done in Clarity. A demo version is available for download on the DataApex website as well.

Screenshots

Instrument window

Instrument window
The Instrument window is the control center of the whole process of data acquisition and evaluation.

 

Data analysis

Data analysis
The Calibration window has two main screens, a global calibration table and dedicated tabs for each compound (on the screenshot). It includes a table with concentration levels matching the response with Amount and a calibration curve. Any point can be temporarily suspended in the graph it will be marked with a circle instead of a cross.

 

Device control

Device control
An extensive list of devices can be controlled by Clarity, operational parameters are stored in method files and chromatograms. It makes methods easily interchangeable between systems.

 

Sample queue

Sample queue
The Sequence table is a user friendly interface to compose a queue for automated injections. The status of each row is indicated by the colored symbols. Copy, paste, fill down, auto increment and time/date fields for file title are available.

 

Peak table and chromatogram

Peak table and chromatogram
Users can easily edit acquired chromatograms visually in the graph or through the integration table. The Result tables (Results, Summary, Column Performance, etc.) can be customized to display the data you want to see. The Summary tab displays data from overlaid chromatograms in one summary table.

 

Report options

Report options
A fully featured report editor allows reporting data on customized templates.

 

Tray menu

Tray menu
The AS 110 can be used with a large variety of well plates and vials. Up to 4 specific reagent positions can be defined.

Downloads

Software

  • 195_0035 – Clarity 5 Antec Analyzers 201403.zip
  • 195_0035 – Clarity 5.0.1.461.zip
  • 195_0035 – Clarity 6 Antec Analyzers 201606.zip
  • 195_0035 – Clarity_6.2.0.280beta.zip

Manuals

Clarity from DataApex is an advanced modular software package for data acquisition, data processing and instrument control. Up to four independent LC systems each with up to 12 detectors can be simultaneously connected. Optional ‘Control modules’ provide integrated control of selected instruments, ‘Extensions’ provide specialized functionality for PDA or GPC analysis. Its wide range of data acquisition interfaces (A/D converters, LAN, USB, and RS232) allows connection to virtually any chromatograph.

To familiarise with Clarity a few hands-on sessions are available. Details are in document 195_7010 'Clarity hands-on training'. A number of screen recordings in the tutorial section show how specific tasks are done in Clarity. A demo version is available for download on the DataApex website as well.

Screenshots

Instrument window

Instrument window
The Instrument window is the control center of the whole process of data acquisition and evaluation.

 

Data analysis

Data analysis
The Calibration window has two main screens, a global calibration table and dedicated tabs for each compound (on the screenshot). It includes a table with concentration levels matching the response with Amount and a calibration curve. Any point can be temporarily suspended in the graph it will be marked with a circle instead of a cross.

 

Device control

Device control
An extensive list of devices can be controlled by Clarity, operational parameters are stored in method files and chromatograms. It makes methods easily interchangeable between systems.

 

Sample queue

Sample queue
The Sequence table is a user friendly interface to compose a queue for automated injections. The status of each row is indicated by the colored symbols. Copy, paste, fill down, auto increment and time/date fields for file title are available.

 

Peak table and chromatogram

Peak table and chromatogram
Users can easily edit acquired chromatograms visually in the graph or through the integration table. The Result tables (Results, Summary, Column Performance, etc.) can be customized to display the data you want to see. The Summary tab displays data from overlaid chromatograms in one summary table.

 

Report options

Report options
A fully featured report editor allows reporting data on customized templates.

 

Tray menu

Tray menu
The AS 110 can be used with a large variety of well plates and vials. Up to 4 specific reagent positions can be defined.

Software

  • 195_0035 - Clarity 5 Antec Analyzers 201403.zip
  • 195_0035 - Clarity 5.0.1.461.zip
  • 195_0035 - Clarity 6 Antec Analyzers 201606.zip
  • 195_0035 - Clarity_6.2.0.280beta.zip

Manuals

Product Images